Commit Graph

16 Commits

Author SHA1 Message Date
edc1b35a62 Pause after network check results before returning to main menu
The serial path already paused at the disconnect-cable prompt. The
network path had no equivalent, causing results to flash and disappear.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 11:31:27 -04:00
6912680ed4 Fix fabric firmware version path — add VikingEnterpriseSolutions key
The Redfish response nests the version under
Oem.VikingEnterpriseSolutions.Version.ActiveFirmwareVersion, not
Oem.Version.ActiveFirmwareVersion. Fixed in both redfish.py
(_get_fabric_fw_version, used by network check and firmware workflow)
and workflow_check.py (serial inline parsing).

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 11:28:07 -04:00
f08550dbea Fix _serial_redfish_request: use rfind for HTTP_CODE: boundary
The curl -w argument in the command echo contains the literal text
'HTTP_CODE:%{http_code}', so raw.find("HTTP_CODE:") hits that first
and cuts search_area off before the actual JSON response body — leaving
data as {}.  Switching to rfind targets the real HTTP_CODE:200 output
that curl appends at the end of the response.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 11:21:17 -04:00
2d27e9760a Extend system check to display MAC, hostname, and link status
_parse_network_data now returns mac, hostname, and link_status extracted
from the Redfish EthernetInterfaces/1 response (MACAddress, HostName,
LinkStatus fields confirmed present in live IOM output).

_print_results gains a second table — Interface Details (IOM | MAC | Hostname)
— between the Network Settings and Firmware Versions tables. Network Settings
table drops the redundant Origin column and adds Link Status instead.

Both _check_via_serial and _check_via_network updated to unpack and pass
the additional fields. fetch_current_config in workflow_serial.py also
updated to use the same address-parsing logic and trimmed table layout.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 11:18:55 -04:00
76ee347d91 Limit serial workflows to IOM1 only — IOM2 unreachable over serial
The serial cable connects to IOM1's console port. IOM2 cannot be queried
or configured via the serial connection. Updated all serial-path code to
reflect this:

workflow_serial.py:
- fetch_current_config: query IOM1 only, single-row table
- collect_network_config: prompt for IOM1 settings only, drop IOM2 section
- apply_configuration: apply to IOM1 only, single-row result table
- print_summary: IOM1-only table, updated warning text

workflow_check.py (_check_via_serial):
- Query IOM1 only for network settings, IOM firmware, and Fabric Card firmware

CLAUDE.md updated to document the IOM1-only serial limitation.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 10:47:12 -04:00
c587e64f9e Fix JSON parsing in _serial_redfish_request when terminal wraps long curl commands
The serial terminal echoes the curl command back before executing it.
The -w format string contains '%{http_code}' which includes a literal '{'.
When the terminal wraps long command lines (IOM2's path is ~70 chars),
that '{' can land at a line boundary, causing find("{") to pick up the
wrong position and produce garbled JSON/error output.

Fix: narrow the JSON search to the text before the HTTP_CODE: marker,
then use rfind("\n{") to find the last newline-prefixed '{'. The actual
curl response always starts on its own line, while the echoed '{http_code}'
is embedded mid-line in the command echo — so rfind("\n{") reliably skips it.

Also tighten the error snippet to use the same search_area bounds so the
displayed error shows actual response content rather than command echo text.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 10:31:00 -04:00
4c820c5086 Auto-detect root password from IOM hostname on serial login
The BMC serial number (e.g. MXE3000048LHA03C) is embedded in the IOM
hostname shown in the serial login prompt. It also doubles as the root
password, so no manual entry is needed.

- If at login prompt: extract serial from 'hostname login:' line
- If already logged in: run 'hostname' on the shell and extract serial
- Falls back to prompt_password() if extraction fails either way

_login_serial_console() now returns (success, password) instead of bool.
Callers in workflow_serial.py and workflow_check.py updated accordingly.
CLAUDE.md updated to document the behaviour and remove it from planned features.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 10:23:13 -04:00
67cbee7897 Fix serial login detection when IOM is already logged in
Adds _at_shell_prompt() helper that detects a shell prompt by checking
whether any line ends with '#' or '# ', rather than using a bare '#' in
response check guarded by 'login' not in output. The old guard caused a
false negative when the IOM echoed 'Last login: ...' text alongside the
prompt, sending an unnecessary login attempt to an active session.

Also broadens _ANSI_RE to catch all CSI escape sequences and two-character
ESC sequences, not just the original five terminal codes.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 10:10:24 -04:00
4b31c8eb8a Clean up main menu and banner UI labels
Remove (stdlib only) from banner subtitle and (serial) from menu option 1.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-09 18:42:02 -04:00
b745643a4b Simplify network workflows to use a single IOM IP address
Either IOM can reach the other via Redfish, so there's no need to collect
separate IOM1/IOM2 addresses. Firmware update and system check now prompt
for one IP per shelf with a note that either IOM's address works.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-04 10:57:44 -04:00
46312e37fb Add firmware/ directory and update file scanning logic
- Add firmware/ directory to hold firmware files for techs cloning the repo
- Scan firmware/ (relative to script location) instead of CWD
- Add .fwc to supported firmware extensions

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-03 18:34:27 -04:00
2b55617db2 Associate password with each shelf for multi-shelf firmware updates
Each ES24N shelf has a unique Admin password (its BMC serial number), so a
single shared password is incorrect for multi-shelf runs. The password prompt
now appears once per shelf inside _collect_shelves(), stored as the first
element of each (password, [(iom, ip), ...]) shelf tuple. _make_targets()
threads the password into each (label, iom, ip, password) target entry, and
_show_fw_versions() uses the per-target password instead of a global one.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-18 08:24:09 -04:00
10354794f8 Add multi-shelf support to firmware update workflow
The firmware update workflow now supports updating any number of shelves in a
single run. After entering IPs for the first shelf, the user is prompted to
add another; this repeats until done. Firmware file and update-type choices
are made once and applied to all shelves sequentially.

_show_fw_versions() updated to accept (label, iom, ip) tuples so the display
label and Redfish path name can differ for multi-shelf tables (e.g. "S1 / IOM1"
vs "IOM1"). Pre- and post-update version tables include the shelf number when
more than one shelf is being updated.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-18 08:20:48 -04:00
3361fdd1a6 Add System Check workflow with serial and network connection options
Adds workflow_check.py: a read-only diagnostic that queries current network
settings and firmware versions (IOM + Fabric Card) from both IOMs. Accessible
via a new main menu option (3 — System Check); Exit moves to option 4.
Supports both serial console (curl over the serial session) and direct network
(HTTPS to management IP) connection methods.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-17 22:25:16 -04:00
d80dac2222 Fix serial workflow: login to IOM console and run curl for Redfish
The Redfish API at 127.0.0.1 is only accessible from within the IOM's
own shell, not directly from the host over the serial cable. The previous
approach of making urllib HTTPS requests from the host to 127.0.0.1 was
fundamentally incorrect.

Changes:
- serial_port.py: add optional per-call timeout override to
  read_until_quiet() so curl responses have enough time to arrive
- workflow_serial.py:
  - add _login_serial_console() — sends username/password over serial
    and waits for a shell prompt before proceeding
  - add _serial_redfish_request() — builds and sends a curl command
    over the serial session, parses HTTP status and JSON from the output
  - fetch_current_config(), apply_configuration(), _apply_iom() now
    accept and use a SerialPort instance via _serial_redfish_request()
  - configure_shelf() calls _login_serial_console() after collecting
    the password, before making any Redfish calls
  - remove unused _redfish_request import (HTTP transport no longer
    used in the serial workflow)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-17 21:55:01 -04:00
cb1c23480e Rename es24n/ to modules/
Update sys.path reference in es24n_conf.py and all documentation
to reflect the new folder name.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-17 19:12:29 -04:00