• Joined on 2025-08-20
scott pushed to main at scott/es24n-conf 2026-04-16 13:50:38 -04:00
b617f48829 Add grace period and retry logic for Fabric Card firmware upload
scott pushed to main at scott/es24n-conf 2026-04-16 13:39:45 -04:00
5c3a0b0ed6 Add production warning to 'Both IOM1 and IOM2' firmware update option
scott pushed to main at scott/es24n-conf 2026-04-16 13:32:29 -04:00
fd38d2518e Confirm success and pause before returning to main menu after firmware update
scott pushed to main at scott/es24n-conf 2026-04-16 13:17:56 -04:00
278c0c03b3 Wait for IOM to come back online after restart instead of fixed sleep
scott pushed to main at scott/es24n-conf 2026-04-16 13:12:39 -04:00
3dc9a5538e Show PercentComplete during firmware update task polling
scott pushed to main at scott/es24n-conf 2026-04-16 13:09:12 -04:00
b2f2dc8768 Increase firmware upload timeout from 120s to 600s
scott pushed to main at scott/es24n-conf 2026-04-16 13:06:58 -04:00
a05ba977d3 Prompt for firmware file once — IOM and Fabric Card use the same file
scott pushed to main at scott/es24n-conf 2026-04-16 12:31:30 -04:00
d7c553fa31 Wait for shell prompt after 'Last login:' banner on fresh serial login
scott pushed to main at scott/es24n-conf 2026-04-16 12:24:19 -04:00
998fb034a2 Prompt for IOM1 or IOM2 in serial system check workflow
scott pushed to main at scott/es24n-conf 2026-04-16 11:43:09 -04:00
d98fcdc265 Update serial cable prompt to say IOM instead of IOM1
scott pushed to main at scott/es24n-conf 2026-04-16 11:41:26 -04:00
c87e1457d4 Fix 'configure another shelf' looping back to main menu
scott pushed to main at scott/es24n-conf 2026-04-16 11:39:37 -04:00
d8a74f02dc Prompt for IOM1 or IOM2 in serial configure workflow
scott pushed to main at scott/es24n-conf 2026-04-16 11:31:29 -04:00
edc1b35a62 Pause after network check results before returning to main menu
scott pushed to main at scott/es24n-conf 2026-04-16 11:28:08 -04:00
6912680ed4 Fix fabric firmware version path — add VikingEnterpriseSolutions key
scott pushed to main at scott/es24n-conf 2026-04-16 11:21:19 -04:00
f08550dbea Fix _serial_redfish_request: use rfind for HTTP_CODE: boundary
scott pushed to main at scott/es24n-conf 2026-04-16 11:18:58 -04:00
2d27e9760a Extend system check to display MAC, hostname, and link status
scott pushed to main at scott/es24n-conf 2026-04-16 10:47:14 -04:00
76ee347d91 Limit serial workflows to IOM1 only — IOM2 unreachable over serial
scott pushed to main at scott/es24n-conf 2026-04-16 10:31:04 -04:00
c587e64f9e Fix JSON parsing in _serial_redfish_request when terminal wraps long curl commands
scott pushed to main at scott/es24n-conf 2026-04-16 10:23:17 -04:00
4c820c5086 Auto-detect root password from IOM hostname on serial login
scott pushed to main at scott/es24n-conf 2026-04-16 10:10:28 -04:00
67cbee7897 Fix serial login detection when IOM is already logged in